GAH 311D9 SMPTE 311 HDTV CAMERA CABLE PVC
- HALOGEN FREE
- 4K-8K
- UHD
APPLICATION
This rugged, extremely durable composite cable complies with the SMPTE 311 standard
and was designed for use with professional HD cameras.
It is used in professional video productions for simultaneous transmission of energy, video, audio and control signals and is intended to interconnect Camera Units and Base Stations in conjunction with the Connector Interface Standard. It is suitable for all new digital camera systems of well-known manufacturers.
| Element 1 | ||||||
| Auxiliary Conductors | 4 x (20 AWG) | |||||
| Inner conductor | 24 x 0.19 mmø Stranded Tinned Copper | |||||
| Insulation | 1,60 mmø, Solid HDPE | |||||
| Core identification | 2 x Black, 2 x White | |||||
| Element 2 | ||||||
| Signal Conductors | 2 x (24 AWG) | |||||
| Insulation | 1,20 mmø, Solid HDPE | |||||
| Core identification | 1 x Red, 1 x Grey | |||||
| Element 3 | ||||||
| Fibre Optic | 2 x 9/125µ Single-Mode G.657.A2 | |||||
| Mode Field Diameter | 9.0 µm ± 1 µm | |||||
| Cladding diameter | 125 µm ± 1 µm | |||||
| Coating material | Acrylate, Diameter 245 µm | |||||
| Buffer material | Thermoplastic, Od:0.9 µm ± 0.05 µm | |||||
| Identification | 1 x Blue, 1x Yellow | |||||
| Element 4 | ||||||
| Central Element | 19 x 0,30mm Steel stranded wire | |||||
| Insulation | 2,1 mmø ;HDPE | |||||
| Identification | White | |||||
| Cable Core | 5,5 mmø, Non Woven tape | |||||
| Screen | Tinned Copper Braiding %95 | |||||
| Sheath | 9,2 mmø FRNC Compound | |||||
| ELECTRICAL DATA | ||||||
| Auxiliary Conductors | Signal Conductors | Overall screen | ||||
| DC resistance | ≤ 35,3 Ω/km | ≤ 97,5 Ω/km | ≤ 20 Ω/km | |||
| Loop resistance | ≤ 43 Ω/km | ≤ 184 Ω/km | ||||
| Insulation Resistance | 10 GΩ x km | 10 GΩ x km | ||||
| Test voltage | 1,75 KVAC | 1.75 KVAC | ||||
| Operating voltage | ≤ 300 VAC | ≤ 300 VAC | ||||
| OPTICAL DATA | ||||||
| Cut-off wavelength | 1100 – 1350 nm | |||||
| Attenuation at 1310 nm (max.) | 0,42 dB/km | |||||
| Attenuation at 1550 nm (max.) | 0,28 dB/km | |||||
| MECHANICAL DATA | ||||||
| Minimum bending radius | 12 x D ( D= outer diameter ) | |||||
| Temperature range | Mobile installation / – 5° C to + 70° C Fixed installation / -30° C to +70° C | |||||